VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:5.5A (RMS) FOR 115 VAC
2.5A (RMS) FOR 230 VAC
INRUSH CURRENT:15A MAX. FOR 115 VAC PER MODULE
30A MAX. FOR 230 VAC PER MODULE
DC Ouput Spec
Output VoltageTD
Output Current Min.
Output Current Max.
Regulation Load
Regulation Line
Output Ripple & Noise Max.[P-P]
+5V
0.5
20
±5%
±1%
50mV
+12V
2.0
30
±5%
±1%
120mV
-12V
0.1
0.5
±10%
±1%
120mV
+3.3V
0.5
20
±5%
±1%
50mV
+5VSB
0.1
2.5
±5%
±1%
50mV
WHEN CONDITIONS OF BOTH +5V/0A +3.3V/0A, MIN LOAD OF 4A AT +12V IS A MUST
Features
* TEMPERATURE RANGE:OPERATING 0℃~40℃, STORAGE -20℃~80℃ * HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 5V MUST BE MAINTAIN 16MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE * EFFICIENCY:84% TYPICAL,AT FULL LOAD 115VAC * LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC * POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms * OVER POWER PROTECTION:110~160% MAX * OVER VOLTAGE PROTECTION: +5V→5.6~6.7V, +3.3V→3.6~4.3V, +12V→13~16V * SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB * SAFETY: MEET UL60950, TUV EN-60950, CB IEC 60950 * WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL